Home > Products > TAJ-8100 polyurethane wear-resistant varnish

TAJ-8100 polyurethane wear-resistant varnish

A single-component, high-performance, high-toughness, high-hardness polyurethane floor coating composed of polyurethane prepolymer and additives. The coating system has the characteristics of dust and moisture resistance, high wear resistance, corrosion resistance and good chemical resistance. It is cost-effective and is an ideal coating system for general production workshops and offices. It is used for concrete protection and is suitable for epoxy floor coating systems and epoxy mortar floor coating systems.

Product Details:

Product Features
●Resistant to corrosion from most acids, alkalis, salts, gasoline, engine oils and other chemicals

●Abrasion and impact resistance

●Seamless, easy to clean, microorganisms are not easy to survive

●Strong adhesion, high toughness

Basic data
color transparent
Mixing ratio
solid,% 40±2
Painting times  1 time
Dry film thickness, um  20~30
Coating rate Dosage: 0.12~0.15kg/m2
Actual value: It is related to many factors such as surface treatment, external environment, construction method, etc.
Main technical indicators (implementing GB/T22374-2008 floor coating material surface coating standard)
Serial number Test items Technical indicators Measured Testing standards
1 Color and appearance Consistent color, smooth and even qualified Visual inspection
2 Drying time, h Touch Dry ≤4 3 GB/T 1728-1989
Get down to business ≤24 12
3 Adhesion, Grade ≤1 0 GB/T 9286-1998
4 Flexibility, mm 1 Pass 1 GB/T1731-1993
5 Hardness (pencil hardness) ≥2 hours 6 GB/T6739-1996
6 Impact resistance (50cm.kg) 50 Pass 50 GB/T1732-1993
7 Abrasion resistance (750g/500r) ≤0.030 0.03 GB/T1768
8 Water resistance (48h) The paint film is complete, does not bubble or peel off, slight discoloration is allowed, and can be restored within 2 hours qualified GB/T1733-1993
9 Resistant to 20% NaOH, 72h The paint film is complete, without blistering or peeling, and slight discoloration is allowed qualified GB/T 9274-1988
10 Resistant to 10% H 2 SO 4 ,48h No bubbling, no shedding, slight discoloration allowed qualified GB/T9274-1988
11 Oil resistance (120# gasoline), 72h No bubbling, no shedding, slight discoloration allowed qualified GB/T1724-1933
Construction reference
Surface treatment
● For all new and old concrete floors, the concrete strength must reach C25 or above. The surface stains, loose soil, moisture, loose old paint film and other attachments must be completely removed until the solid concrete is exposed. For concrete contaminated by chemicals or other substances, they should be removed until the solid concrete is exposed. Make the surface clean, dry and flat.

● Old floors with paint
Completely grind away loose or incompatible old coatings to expose the concrete surface. Clean, dry and intact compatible coatings do not need to be removed.

● Oily floors
Oil stains will seriously affect the adhesion of floor coatings to the base surface. Oily floors must be completely cleaned and polished.

● New concrete floors
Make sure the floor has exceeded the maintenance period and the moisture content of the floor is less than 6%. It is critical to use mobile sandblasting tools and grinding equipment to treat the concrete surface to achieve the correct surface roughness.

Paint mixing method
Apply directly within the service life.
Construction conditions
Painting environment temperature range: 5~35℃. The base surface temperature is at least 3℃ higher than the air dew point temperature.
Painting environment humidity range: Relative humidity <85%
Ventilation conditions: Ensure that the construction site is ventilated and dust-free. However, there should be no strong wind to avoid bringing in dust and affecting the appearance.
Construction data
● Mixing period:
4 hours after opening the can
● Construction method

Airless spray, air spray, brush and roller
Roller coating Large area construction use
Spraying Can be applied using conventional air spray or airless spray
Brush It is recommended to use a soft-bristled brush for small areas.

● Thinner —

● Drying time and coating interval
It is related to the temperature and humidity of the coating environment. Usually, the coating interval is 12 hours under standard conditions (25℃, relative humidity 60%)

● Coating matching
Applicable substrate Cement or concrete floor
Applicable coating Epoxy primer
Solvent-free polyurethane midcoat, epoxy midcoat

Shelf life
From the date of production, if stored according to the storage conditions, the shelf life of the product is 12 months.
Storage and transportation
The paint should be sealed and stored in a dry, cool and well-ventilated place, avoiding high temperature and fire.
During transportation, the environment of the carriage should be dry and closed, the materials should be stacked stably, and the relevant regulations should be met.
Safety measures
Product safety and health data are available upon request. The following measures should be ensured during any paint application:

● Avoid contact with skin and eyes.

● If paint comes into contact with skin, wash with warm water and/or an appropriate detergent. If paint comes into contact with eyes, rinse with plenty of water and seek medical attention immediately.

● Ensure good ventilation.

● Paint contains flammable substances. Please keep away from sparks and prohibit smoking in the vicinity.

● Comply with all health and safety regulations on site.

Attention
The information provided in this manual is the most comprehensive and correct information we have at present. Since the conditions of product use are beyond our control, the information here does not contain any guarantee. Due to the continuous development of our company’s products and production processes, all information here is subject to our confirmation.

Write to us