●Strong adhesion
●Excellent color and gloss retention
●Good weather resistance
color | Various |
Mixing ratio | — |
solid,% | 75±2 |
Painting times | 1 time |
Dry film thickness, um | 15~20 |
Coating rate | Dosage: 0.15kg/m2 |
Actual value: It is related to many factors such as surface treatment, external environment, construction method, etc. | |
Technical indicators (implement GB/T22374-2008 floor coating material surface coating standard) |
Serial number | Test items | Technical indicators | Measured | Testing standards | |
1 | Color and appearance | Consistent color, smooth and even | qualified | Visual inspection | |
2 | Drying time, h | Touch Dry | ≤4 | 4 | GB/T 1728-1989 |
Get down to business | ≤24 | 12 | |||
3 | Adhesion, Grade | ≤1 | 0 | GB/T 9286-1998 | |
4 | Flexibility, mm | 1 Pass | 1 | GB/T1731-1993 | |
5 | Hardness (pencil hardness) | ≥B | B | GB/T6739-1996 | |
6 | Impact resistance (50cm.kg) | 50 Pass | 50 | GB/T1732-1993 | |
7 | Abrasion resistance (750g/500r) | ≤0.030 | 0.03 | GB/T1768 | |
8 | Water resistance (48h) | The paint film is complete, does not bubble or peel off, slight discoloration is allowed, and can be restored within 2 hours | qualified | GB/T1733-1993 | |
9 | Resistant to 20% NaOH, 72h | The paint film is complete, without blistering or peeling, and slight discoloration is allowed | qualified | GB/T 9274-1988 | |
10 | Resistant to 10% H 2 SO 4 ,48h | No bubbling, no shedding, slight discoloration allowed | qualified | GB/T9274-1988 | |
11 | Oil resistance (120# gasoline), 72h | No bubbling, no shedding, slight discoloration allowed | qualified | GB/T1724-1933 |
● Old floors with paint
Completely grind away loose or incompatible old coatings to expose the concrete surface. Clean, dry and intact compatible coatings do not need to be removed.
● Oily floors
Oil stains will seriously affect the adhesion of floor coatings to the base surface. Oily floors must be completely cleaned and polished.
● New concrete floors
Make sure the floor has exceeded the maintenance period and the moisture content of the floor is less than 6%. It is critical to use mobile sandblasting tools and grinding equipment to treat the concrete surface to achieve the correct surface roughness.
Painting environment humidity range: Relative humidity is less than 80%.
Ventilation conditions: The paint system contains organic solvents, so the construction site should be ventilated and dust-free. However, there should be no strong wind to avoid dust from being brought in and affecting the appearance.
● Construction method
Airless spray, air spray, brush and roller | |
Roller coating | Large area construction use |
Spraying | Can be applied using conventional air spray or airless spray |
Brush | It is recommended to use a soft-bristled brush for small areas. |
● Drying time and coating interval
are related to the temperature and humidity of the coating environment. Usually, the coating interval is 24 hours under standard conditions (25℃, relative humidity 60%), which can be extended appropriately when the temperature is low.
● Coating matching
Applicable substrate Cement or concrete floor
Applicable coating —
During transportation, the environment of the carriage should be dry and closed, the materials should be stacked stably, and the relevant regulations should be met.
● Avoid contact with skin and eyes.
● If paint comes into contact with skin, wash with warm water and/or an appropriate detergent. If paint comes into contact with eyes, rinse with plenty of water and seek medical attention immediately.
● Ensure good ventilation.
● Paint contains flammable substances. Please keep away from sparks and prohibit smoking in the vicinity.